Upgrade and Maintenance Manual 191
Expansion cards and backup units
Ê Disconnect the BBU cable from the BBU as described in section
"Disconnecting the BBU cable from the BBU" on page 186.
9.5.6.3 Installing the new BBU
Ê Connect the BBU cable to the BBU as described in section "Connecting the
BBU cable to the BBU" on page 172.
Ê Install the BBU in the holder as described in section "Installing the BBU in
the holder" on page 173.
Ê Install the BBU with the holder as described in section "Installing the BBU
with the holder" on page 174.
9.5.6.4 Concluding steps
Ê "Installing the riser module 3" on page 61
Ê "Reassembling" on page 52
Ê "Connecting the server to the mains" on page 57
Ê "Updating RAID controller firmware" on page 73
Ê "Enabling SVOM boot watchdog functionality" on page 78
Ê "Switching on the server" on page 58
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 12 hours before the BBU will initiate a
recalibration cycle.
Ê Enter the ServerView RAID Manager and check the current BBU status.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê If the BBU is shown as bad or defective, do not power off the server for at
least 12 hours to allow the charge and calibration cycles to finish.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX200 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX200 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX200 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX200 S8
CategoryServer
LanguageEnglish

Related product manuals