17.2.1.5 Indicators on power supply units
Figure 261: Indicator on the power supply unit
1 Indicator on the hot-plug power supply unit (two colors)
800 W power supply unit:
Flashes green when the server is switched off, but mains voltage is
present (standby mode).
Lights up green when the server is switched on and functioning
properly.
Flashes orange when a predictable error has been detected, but the
power supply unit is still running.
Lights up orange if no mains voltage is present or the power supply unit
has failed.
450 W power supply unit:
Flashes green when the server is switched off, but mains voltage is
present (standby mode).
Lights up green when the server is switched on and functioning
properly.
Lights up orange in case of OCP/OVP or when the fan of the power
supply unit has failed.