EasyManua.ls Logo

Fujitsu PRIMERGY RX200 S8 - Installing a Memory Module

Fujitsu PRIMERGY RX200 S8
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RX200 S8
Upgrade and Maintenance Manual 205
Main memory
In order to satisfy cooling requirements, populate memory channels on
alternating sides of the processor:
10.2 Installing a memory module
10.2.1 Preliminary steps
Ê "Disabling SVOM boot watchdog functionality" on page 64
Ê "Disabling BitLocker functionality" on page 63
Ê "Shutting down the server" on page 46
Ê "Disconnecting the server from the mains" on page 47
Ê "Getting access to the component" on page 47
Ê "Removing the air duct" on page 62
10.2.2 Selecting the memory slot
Ê Choose the memory slot according to the configuration rules in "Basic
information" on page 196.
Order CPU 1 CPU 2
1 Channel A Channel E
2 Channel C Channel G
3 Channel B Channel F
4 Channel D Channel H
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: tool-less

Table of Contents

Other manuals for Fujitsu PRIMERGY RX200 S8

Related product manuals