328 Upgrade and Maintenance Manual
RX200 S8
Appendix
The LEDs have the following meaning:
LED Indicator Meaning
A - Identification blue on server is identified via the ServerView
Operations Manager
blue flashing local monitor off
B - CSS
(Customer Self
Service)
off no error (CSS component)
yellow on indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
C - GEL
(Global Error
LED)
off no error (non CSS component)
orange on indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
over temperature measured by one of
the sensors
sensor is defective
CPU error
software detected an error
F - Controller off PCI card okay
orange on PCI card failure (PCI card installed on riser
card)
G - CPU off CPU okay
orange on CPU failure
H - Memory
module
off memory module running
orange on memory module failure
I - iRMC off iRMC S4 inactive
green flashing iRMC S4 okay
K - Fans off fan running
orange on fan failure
L - Battery off battery running
orange on battery failure

Table of Contents