EasyManua.ls Logo

Fujitsu PRIMERGY RX2540 M1 - Concluding Steps; Removing 3.5-Inch HDD Modules; Preliminary Steps

Fujitsu PRIMERGY RX2540 M1
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
118 Upgrade and Maintenance Manual
RX2540 M1
Hard disk drives / solid state drives
7.2.2.4 Concluding steps
Ê "Performing a RAID array rebuild" on page 93
7.2.3 Removing 3.5-inch HDD modules
7.2.3.1 Preliminary steps
Ê If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Utility.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0
array if defective.
V CAUTION!
Removing an operational HDD module will
result in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild
will be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 93.