Processors
11.4 Upgrading or replacing processors
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.4.1 Preliminary steps
Ê "Disabling or suspending BitLocker functionality" on page 69
Ê "Disabling SVOM boot watchdog functionality" on page 70
Ê "Locating the defective server" on page 51
Ê "Shutting down the server" on page 53
Ê "Disconnecting power cords" on page 54
Ê "Getting access to the component" on page 55
Ê "Removing processor heat sinks" on page 311
11.4.2 Upgrading or replacing a processor
I This description applies to the following procedures:
Installing the second processor in a single-processor configuration
Transfering a processor after replacing the system board (see section
"Replacing the system board" on page 397)
In case of installing a second processor remove the protective cover as
described in section "Opening the load plate" on page 288