EasyManua.ls Logo

Fujitsu PRIMERGY RX2540 M1 - 10.3 Removing memory modules

Fujitsu PRIMERGY RX2540 M1
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
282 Upgrade and Maintenance Manual
RX2540 M1
Main memory
10.3 Removing memory modules
10.3.1 Preliminary steps
Ê "Disabling or suspending BitLocker functionality" on page 69
Ê "Disabling SVOM boot watchdog functionality" on page 70
Ê "Locating the defective server" on page 51
Ê "Shutting down the server" on page 53
Ê "Disconnecting power cords" on page 54
Ê "Getting access to the component" on page 55
10.3.2 Removing a memory module
Ê Identify the desired memory slot see section "Memory sequence" on
page 273.
V CAUTION!
Ensure to maintain an operational configuration when removing
memory modules. For additional information, please refer to section
"Basic information" on page 272.
Figure 177: Removing memory modules (A)
Ê Eject the desired memory module by pressing out the securing clips at each
end of the memory slot.
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: tool-less

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M1

Related product manuals