370 Upgrade and Maintenance Manual
RX2540 M1
System board and components
Ê Download the desired ESXi Recovery CD ISO image, listed under Tools.
Ê Unpack and burn the image to a CD.
Ê Ensure that no other USB storage device is connected to the server beside
the UFM.
Ê Insert the Recovery Tools CD into your CD / DVD drive and reboot the
server.
The server should now boot from the Recovery Tools CD.
Ê Follow the on-screen instructions to initiate the installation.
After the flash process is complete, you will be asked to reboot the system.
I IFor the Japanese market, follow the instructions provided separately.
14.3.2 Removing the UFM
14.3.2.1 Preliminary steps
Ê "Disabling or suspending BitLocker functionality" on page 69
Ê "Locating the defective server" on page 51
Ê "Shutting down the server" on page 53
Ê "Disconnecting power cords" on page 54
Ê "Getting access to the component" on page 55
Field Replaceable Unit
(FRU)
Hardware: 5 minutes
Tools: Phillips PH0 / (+) No. 0 screw driver

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2540 M1

Related product manuals