W
ait about 30 seconds to allow the HDD to spin down.
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Pull the HDD module completely out of its bay
.
Installing a 3.5-inch dummy module
CAUTION
If the removed HDD module is not replaced immediately, always
replace a dummy module into the unused HDD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 66: Installing a 3.5-inch HDD dummy module
Push the dummy module into the empty bay until it engages (1).
If applicable, insert the dummy lock (2).
Concluding steps
If applicable, "Installing the front cover with lock" on page
71.
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M7 Upgrade and Maintenance Manual 155