Loading...
Installing the rear 2x 2.5-inch HDD backplane
Figure 123: Installing the rear 2x 2.5-inch HDD backplane
Position the rear HDD backplane.
Fasten the screw (see circle).
Connect the cables to the rear HDD backplane.
The cables are equipped with labels showing the right connector.
For the cable plan, see "Appendix B" on page
559.
CAUTION
Incorrect cabling may cause wrong LED identification of the HDD/SSD.
Misleading LED could lead to swapping out the wrong HDD/SSD, and
that will result in data loss.
Check the correct cabling using the labels on the cables and the
cable plans.
Concluding steps
Insert all HDD/SSD modules, see "Installing 2.5-inch HDD/SSD modules"
on page
177.
Ensure that you install the HDD/SSD module in the bay it was located
before the HDD backplane replacement.
Insert all dummy modules, see "Installing a 2.5-inch HDD/SSD dummy
module" on page
182.
Hard disk drive (HDD) / solid state disk (SSD)
238 Upgrade and Maintenance Manual RX2540 M7