Loading...
If ServerView related tools are applied (i.e. ServerView Agentless Service or
ServerV
iew ESXi CIM Provider) or BIOS is executed at the same time as the
power cord is connected after the iRMC microSD card replacement, see
"iRMC S6 firmware recovery guidelines after replacing an iRMC microSD
card" on page 509 and "BIOS recovery guidelines after replacing an iRMC
microSD card" on page 509.
Check with the system administrator for the ServerView related tools.
Preliminary steps
"Locating the defective server" on page 47.
If applicable, "Removing the front cover with lock" on page 49.
"Shutting down the server" on page 50.
"Disconnecting the power cord" on page 50.
"Getting access to the component" on page 55.
If applicable, remove the expansion card from slot 5 and slot 6, see
"Removing an expansion card" on page 278.
Replacing the iRMC microSD card
Remove the defective iRMC microSD card, see "Removing the iRMC
microSD card" on page 506.
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
After removing the iRMC microSD card, hand the card over to
the customer.
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
Install the new iRMC microSD card, see "Installing the iRMC microSD card"
on page 504.
System board and components
508 Upgrade and Maintenance Manual RX2540 M7