If a DC power cord is used, the server must be connected to a proper DC
source and earth ground stud/end.
Ensure that the server is connected to a properly grounded power outlet
close to the server.
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
The On/Of
f button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing
disconnect the server completely from the mains power supply, unplug all
power plugs from the properly grounded power outlets.
Always connect the server and the attached peripheral devices to the same
power circuit. Otherwise you run the risk of losing data if, for example, the
server is still running but a peripheral device (e.g. memory subsystem) fails
during a power outage.
The adequately shielded data cables must be used.
All data and signal cables must have sufficient shielding. The use of cable
type S/FTP Cat5 or higher is recommended. Use of unshielded or badly
shielded cables may lead to increased emission of interference and/or
reduced fault-tolerance of the device.
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards
or ISO/IEC 11801 standard respectively. The minimum requirement is a
Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for
Gigabit Ethernet.
Route the cables in such a way that they do not create a potential hazard
(ensure that no-one can trip over them) and that they cannot be damaged.
When connecting the server, see the relevant instructions in this manual.
Never connect or disconnect data transmission lines during a storm (risk of
lightning hazard).
Ensure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside
the server (risk of electric shock, short circuit).
In emergencies (e.g. damaged casing, controls or cables, penetration of
liquids or foreign bodies), contact the server administrator or your customer
service team. Only disconnect the server from the mains power supply if
there is no risk of harming yourself.
Important information
TX2550 M5 Upgrade and Maintenance Manual 35

Table of Contents

Other manuals for Fujitsu PRIMERGY TX2550 M5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX2550 M5 and is the answer not in the manual?

Fujitsu PRIMERGY TX2550 M5 Specifications

General IconGeneral
Tcase78 °C
Scalability2S
Processor cache13.75 MB
Processor cores10
Processor model4210
System bus rate- GT/s
Processor socketLGA 3647 (Socket P)
Processor threads20
Processor codenameCascade Lake
Execute Disable BitYes
Processor frequency2.2 GHz
Processor lithography14 nm
Processor manufacturerIntel
Processor package size76.0 x 56.5 mm
Processor boost frequency3.2 GHz
Processor operating modes64-bit
Supported instruction setsAVX-512
Thermal Design Power (TDP)85 W
Number of processors installed1
Maximum number of PCI Express lanes48
Memory types supported by processorDDR4-SDRAM
Memory clock speeds supported by processor2400 MHz
Maximum internal memory supported by processor1024 GB
Memory slots12
Internal memory16 GB
Memory clock speed2933 MHz
Maximum internal memory1500 GB
HDD size2.5 \
RAID levels0, 1, 5, 6, 10, 50, 60
HDD interfaceSerial ATA, Serial Attached SCSI (SAS)
Optical drive typeNo
Total storage capacity0 GB
Maximum storage capacity- TB
Number of HDDs supported8
Chassis typeTower
Product colorBlack, Red
Operating system installed-
Compatible operating systemsMicrosoft Hyper-V Server 2016 Microsoft Windows Server 2016 Datacenter Microsoft Windows Server 2016 Standard Microsoft Windows Server 2016 Essentials Microsoft Windows Storage Server 2016 Standard Microsoft Hyper-V Server 2012 R2 Microsoft Windows Server 2012 R2 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Essentials Microsoft Windows Storage Server 2012 R2 Standard VMware vSphere 6.5 VMware vSphere 6.0 SUSE Linux Enterprise Server 12 Red Hat Enterprise Linux 7 Red Hat Enterprise Linux
Power supply800 W
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeGigabit Ethernet
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)10 - 85 %
CertificationCB, RoHS, WEEE, GS, CE, CSAc/us, FCC Class A, VCCI, KN32, KN35, CCC, C-Tick
USB 2.0 ports quantity0
Ethernet LAN (RJ-45) ports2
USB 3.2 Gen 1 (3.1 Gen 1) Type-A ports quantity6
PCI Express slots version3.0
On-board graphics card modelNot available
Processor ARK ID193384
Weight and Dimensions IconWeight and Dimensions
Depth177 mm
Width448 mm
Height736 mm