To eject the iRMC microSD card, gently push it in and then let go (1).
Pull the iRMC microSD card straight out of its slot (2).
CAUTION
(not valid for Europe, Middle East, India and Africa)
The iRMC microSD card contains customer information.
After removing the iRMC microSD card, hand the card over to
the customer.
If the customer requests disposal of the defective microSD card,
proceed as follows: Using a pair of side-cutting pliers, cut the
microSD card in half.
Concluding steps
If applicable, install the riser module, see "Installing the riser module" on
page
87
.
"Reassembling" on page 68.
"Connecting the power cord" on page 82.
"Switching on the server" on page 83.
14.5.4 Replacing the iRMC microSD card
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Tools: a pair of side-cutting pliers
Preliminary steps
"Locating the defective server" on page 47
.
"Shutting down the server" on page 49.
"Disconnecting the power cord" on page 50.
"Getting access to the component" on page 51.