When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
Restart your server.
As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Select the Save & Exit menu.
Select Save Changes and Exit or Save Changes and Reset.
Verify that the Global Error indicator stops flashing.
"Resuming BitLocker functionality" on page
130.
1
1.4 Replacing a CPU or heat sink
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
CAUTION
CPUs are extremely sensitive to electrostatic discharge and therefore
must always be handled with care.
After a CPU has been removed from its protective sleeve or from its
socket, place it upside down on a nonconducting, antistatic surface.
Never push a CPU over a surface.
Processor (CPU)
420 Upgrade and Maintenance Manual TX2550 M5