Fujitsu PRIMERGY TX2550 M5 - Installing 2.5-Inch Pcie SSD Modules

Fujitsu PRIMERGY TX2550 M5
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing the defective 2.5-inch HDD/SSD module
Remove the HDD/SSD module, see "Removing a 2.5-inch HDD/SSD
module" on page 222
.
If applicable, remove the HDD/SSD from the installation frame, see
"Handling HDDs or SSDs without installation frame" on page 166.
Installing the new 2.5-inch HDD/SSD module
If applicable, install the HDD/SSD in the installation frame, see "Handling
HDDs or SSDs without installation frame" on page 166.
Install the HDD/SSD module, see "Installing a 2.5-inch HDD/SSD module"
on page 219.
Concluding steps
When working on a floorstand model, close the HDD bay cover, see
"Installing the accessible drive bay cover" on page 78.
If the HDD/SSD is configured using a RAID controller with a RAID level
higher than "0", the rebuild will start automatically, see "Performing a RAID
array rebuild" on page 131.
7.5.6 Installing 2.5-inch PCIe SSD modules
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools: tool-less
This procedure is valid, if the PCIe SSD module is controlled by an
onboard controller or by a Retimer card. For more information, see the
"NVMe User Guide".
If the PCIe SSD module is controlled by a RAID controller of the PRAID
EP5x0i family, the PCIe SSD module can be installed during operation
(hot-plug), see "Installing a 2.5-inch HDD/SSD module" on page
219.