Preliminary steps
"Suspending BitLocker functionality" on page 107
.
"Shutting down the server" on page 49.
"Disconnecting the power cord" on page 50.
"Getting access to the component" on page 51.
"Removing the system air duct" on page 67.
Removing a memory module
Figure 260: Removing memory modules (A)
Eject the desired memory module by pressing out the securing clips at each
end of the memory slot.
Figure 261: Removing memory modules (B)
Remove the ejected memory module.
If applicable, install a dummy module, see "Installing a memory dummy
module" on page
406.
Concluding steps
"Installing the system air duct" on page 68.
"Reassembling" on page 68.
Main memory
404 Upgrade and Maintenance Manual TX2550 M5