4. Operation of SEP Related Controllers
209
[3] Examples of position setting operations
Respective operations are explained by giving specific examples.
1) Setting of position, speed, acceleration and deceleration
An example of operation mode 0 (standard) is explained.
Set positions to move the actuator back and forth between 10.0 mm and 100.0 mm.
Forward end position: 100.0 mm, backward end position: 10.0 mm, back-and-forth speed:
50 mm/sec, back-and-forth acceleration: 0.3 G, back-and-forth deceleration: 0.3 G
No. Operation Screen Remarks
1 On the SEP menu screen:
Touch [Pos.Edit].
2 If the position data edit
password is other than
“0000,” the password input
screen appears.
Input a position data edit
password and touch [ENT].
You can set a position data
edit password from “Position
data edit password” on the
parameter edit screen.
3 Set the position, acceleration
and deceleration relating to
the backward end position.
Touch [Backward Position].
Touch [Menu] to return to the
SEP menu screen.
4 Touch the value in Position.
The numeric keypad appears.
Touch [1] and [0], and
touch [ENT].
Touch [Menu] to return to the
position setting screen.
5 10.00 is shown in Position.
Touch [Menu] to return to the
position setting screen.

Table of Contents