Parameter
Address Name / seng range / [default seng] Info
0x500A:025 Addional gearbox factor - numerator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
t
ed.
0x500A:026 Addional gearbox factor - denominator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
ted.
0x500A:033 Gearbox factor - nominator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
t
ed.
0x500A:034 Gearbox factor - denominator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
t
ed.
0x500B:033 Gearbox factor - nominator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
ted.
0x500B:034 Gearbox factor - denominator
1 ... [1] ... 4294967295
•
Seng can only be changed if the inverter is inhibi-
ted.
Example of how to calculate the rao
Example
calculaon
0x500A : 033 z2*z4 88*72 6336
i 58.667
0x500A : 034 z1*z3 12*9 108
= = = = =
Gearbox factor numerator 0x500A:033
Gearbox factor denominator 0x500A:034
Tab. 1: Example of how to calculate the gearbox rao
Technology applicaon (TA) basic sengs
Kinemac
sengs
Motor/encoder gearbox rao
48