Checking Transmission Oil Pressure
The transmission oil pressure must be within the correct range for the drive wheels to function correctly.
IMPORTANT:
The rated charge pressure MUST be maintained under all conditions of operation to prevent damage to the transmission.
If the TRANS OIL PRESSURE warning is displayed, shut down the engine, and proceed as follows:
1. Check the hydraulic fluid level in the tank. For instructions, refer to 5.11.1 Checking and Filling Hydraulic Oil, page 419.
2. Check the hoses and lines for leakage.
3. Check the charge pressure relief valve. For instructions, refer to Checking Charge Pump Pressure, page 429.
4. If charge pressure still cannot be maintained, do NOT operate the windrower. Contact your MacDon Dealer.
Checking Charge Pump Pressure
The charge pump oil pressure must be within the correct range for the drive wheels to function correctly.
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operators seat for any reason.
The incorrect charge pressure setting may result in the charge pressure pump being unable to build the required system
pressure and/or inadequate loop flushing flows.
The correct charge pressure MUST be maintained under all conditions, in order to maintain pump control performance and
to operate the brake release.
Check the charge pump pressure as follows:
1. Open the hood fully. For instructions, refer to 5.3.3 Opening Hood Highest Position, page 317.
2. Attach a 04000 kPa (0600 psi) pressure gauge to a hose long enough to allow the pressure gauge to be read from
the operators seat.
1000796
A
Figure 5.198: Charge Pump Test Port
3. Locate test port (A) on the charge filter head. Clean the test
port fitting, and then attach the hose to the fitting.
4. Start the engine. Set the throttle to the idle position. The
pressure should be 16552241 kPa (240325 psi) when the
hydraulic oil reaches a temperature of 40°C (100°F).
5. Record the reading and shut down the engine.
6. If the pressure reading is NOT within the appropriate range,
contact your MacDon Dealer.
7. If the pressure reading is within the appropriate range,
remove the hose from the test port and close the hood. For
instructions, refer to 5.3.4 Closing Hood Highest Position,
page 318.