7 APPLICATION INSTRUCTIONS
7.27 Module Access Instructions
1071
7
If an I/O number other than the start I/O number is specified in (H) for a module having 32 or more I/O points, module
information in which only the module mount status is on and any other status is off is stored. In the following program
example, when M0 turns on, the information on the module mounted at I/O number 0050H is stored in D0 and later.
Operation error
[Result of reading]
Only the module mount status is on because the I/O number in the latter 16 points of the RJ71EN71 is specified by (H).
(1) A 32-point module is connected in the latter 16 points.
(2) All 0s because the latter 16 points of a 32-point module is specified in n1.
(1) All 0s because the latter 16 points of a 32-point module is specified in n1.
Module information of RX10 is read.
(1) Module mounting status
(2) Start of slot
(3) CPU No. 1 control
(4) MELSEC iQ-R series module
(5) Input module
(6) 16-point module
(1) Module access enabled
(2) Fixed to 0
(3) Not during online module change
(4) Fixed to 0
(5) No fuse blown
(6) Fixed to 0
(7) Fixed to 0
(8) Inter-module synchronized
(9) Fixed to 0
(10)Module ready
(11)Normal operation (no module error)
Error code
(SD0)
Description
2800H The value set to (H) is out the range, 0 to FFH.
3405H The value set to (n) is out of the range, 0 to 256.
The total of the values in (H) and (n) is 257 or greater.
RX10 RX10RX10
RJ71EN71
RX10CPU RX10
0000H 0010H 0020H 0030H 0040H 0060H
PW
(H) (n)(d)
M0
UNIINFRD D0 K2K5
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
D0
1 0000 00000 0000 00
(1) (2)
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
D1
0 0000 00000 0000 00
(1)
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
D2
1 1000 01110 0000 00
(1) (2) (3) (4) (5) (6)
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
D3
1 0000 00010 0001 00
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)

Table of Contents