1394
11 PROCESS CONTROL INSTRUCTIONS
11.7 Auto Tuning
Input data
Block memory
Operation constant
Loop tag memory
The loop tag memory occupies 96 words from the specified start device.
Operand: (s1)
Device Symbol Name Recommended range Data type Standard
value
Set by
+0
+1
E1 Input value -999999 to 999999 [%] Single-precision
real number
User
+2 e1 Auto tuning start
signal
0: Stop/End
1: Start
16-bit unsigned
binary
0User
Operand: (d1)
Device Symbol Name Recommended range Data type Standard
value
Set by
+0 BB BB1 Alarm
BB16
0: Not completed
1: Completed
BB1 to BB8
0: No alarm
1: Alarm
16-bit unsigned
binary
System
BB2 Input upper limit
alarm
BB3 Input lower limit
alarm
BB4 Output upper
limit alarm
BB5 Output lower
limit alarm
BB6 Timeout alarm
BB7 Control mode
alarm
BB8 Identification
alarm
BB1
6
Auto tuning
completion
Operand: (s2)
Device Symbol Name Recommended range Data type Standard
value
Set by
+0 PN Operation mode 0: Reverse action
1: Direct action
16-bit unsigned
binary
0 User
Operand: (d2)
Device Symbol Name Recommended range Data type Standard
value
Set by
+1 MODE Control mode 0 to FFFFH 16-bit unsigned
binary
8H User/
system
b15 b0
...
e1
b15
...
b2 b1 b0b5 b4b7 b6 b3
BB3
BB4
BB5
BB6
BB7
BB8
BB16
BB2
BB1
b15 b9b10 b1b2b3b4b5b6b7b8 b0
CMV
CSV
LCM
LCA
LCC
MAN
AUT
CAS
CMB
CAB
CCB
...