15 NETWORK COMMON INSTRUCTIONS
15.1 Link Dedicated Instructions
+4 Target network number [CC-Link IE Controller Network or CC-Link IE Field Network]
Specify the network number (1 to 239) of the target station.
(s1)+4
Network No.:
1 to 239
(s1)+5
Station No.:
1 to 120, 125, 126
Group number:
0081H to 00A0H
All-station
specification:
00FFH
(s1)+4, 5
IP address:
00000001H to
FFFFFFFEH
(1 to 4294967294)
User
[Ethernet]
When "0" is specified in bit 15 of (s1)+0
Specify the network number (1 to 239) of the target station.
When "1" is specified in bit 15 of (s1)+0 (Ethernet only)
Specify the IP address (third and fourth octets) of the target station.
b8 to b15: 3rd octet
b0 to b7: 4th octet
+5 Target station number [CC-Link IE Controller Network]
Specify the station number of the target station.
(1) Station number specification
1 to 120: Station number
(2) Group number specification
0081H to 00A0H: All stations with group numbers 0001H to 0020H
(Can be set when the execution type specified by (s1) is "0: No arrival
acknowledgment")
(3) All-station specification
00FFH: All stations of target network number (broadcast (excluding the own
station))
(Can be set when the execution type specified by (s1) is "0: No arrival
acknowledgment")
User
[CC-Link IE Field Network]
Specify the station number of the target station.
(1) Station number specification
125: Master station
126: Master operating station
1 to 120: Local station, intelligent device station, submaster station
(2) All-station specification
00FFH: All stations of target network number (broadcast (excluding the own
station))
(Can be set when the execution type specified by (s1) is "0: No arrival
acknowledgment")
[Ethernet]
When "0" is specified in bit 15 of (s1)+0
Specify the station number of the target station.
(1) Station number specification
1 to 120: Station number
(2) Group number specification
0081H to 00A0H: All stations with group numbers 0001H to 0020H
(Can be set when the execution type specified by (s1) is "0: No arrival
acknowledgment")
(3) All-station specification
00FFH: All stations of target network number (broadcast (excluding the own
station))
(Can be set when the execution type specified by (s1) is "0: No arrival
acknowledgment")
When "1" is specified in bit 15 of (s1)+0
Specify the IP address (first and second octets) of the target station.
b8 to b15: 1st octet
b0 to b7: 2nd octet
+6 Not used 
+7 Number of resends Effective when the execution type specified by (s1) is "1: Arrival acknowledgment
used".
Before instruction execution
Specify the number of resends to be performed if the instruction is not completed
within the monitoring time specified by (s1)+8.
0 to 15 (times)
At completion of instruction
The number of resends performed (result) is stored.
0 to 15 (times)
0 to 15 User/
system
Operand: (s1)
Device Item Description Setting range Set by
b15 b7b8
……
b0
b15 b7b8
……
b0