EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 1575

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 ETHERNET INSTRUCTIONS
16.6 Clearing Error Information
1573
16
Processing details
These instructions clear following error information with regard to the module specified by (U).
*1 Only 0001H to 0010H can be specified when the network type is Q-compatible Ethernet.
*2 The error log can be cleared only when the network type is Q-compatible Ethernet.
*3 The initial error can be cleared only when the network type is Ethernet.
Operation error
Target name Clear target
specification
(s)+2
Clear function
specification
(s)+3
Specify the error
information to clear.
Buffer memory address
Network type:
Ethernet
Network type: Q-
compatible
Ethernet
Initial error 0000H 0000H Initial error code 1900025 105
Open error 0001H to 0080H
*1
0000H Open error code of
connection
The open error code of
connection No. 1 to 128
(0001H to 0080H) is
cleared.
100 to 163, 2000100
to 2000163
124, 134, 144, 154,
164, 174, 184, 194,
22564, 22574, 22584,
22594, 22604, 22614,
22624, 22634
Error log
*2
0100H FFFFH Error log 227 to 372
Communication
status (PORT1)
Status by
protocol
0101H FFFFH PORT1 communication
status by protocol
5000 to 5188 376 to 511
Communication
status
(PORT2)
*3
Status by
protocol
8101H FFFFH PORT2 communication
status by protocol
2005000 to 2005188
All error information FFFFH FFFFH All the information above is
cleared.

Error code
((s)+1)
Description
C000H to CFFFH MELSEC iQ-R Ethernet User's Manual (Application)

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals