1616
18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
18.4 Writing Data to the Intelligent Device Station/Remote Device Station (32-bit Address Specified)
■Description, range, data type
*1 A channel is used only for the REMFR, REMTO, REMFRD, and REMTOD instructions.
The same channel number used for the link dedicated instructions (such as the READ instruction) can be set.
*2 This is the start I/O number (first three digits in four-digit hexadecimal representation) of intelligent function modules.
*3 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
*4 When a station in a redundant system is targeted, specify the station number in the control system by using the module FB
(RedundantSystem_GetAddress).
MELSEC iQ-R Ethernet/CC-Link IE Function Block Reference
■Applicable devices
*1 FX and FY cannot be used.
*2 FD cannot be used.
*3 T, ST, C, and FD cannot be used.
Operand Description Range Data type Data type (label)
(J) Target network number 1 to 239 16-bit unsigned binary ANY16
(s1) Channel of the own station, which is used for the
instruction
*1
1 to 32 16-bit unsigned binary ANY16
(s2) Target station number
*4
1 to 120 16-bit unsigned binary ANY16
(s3) Start I/O number of target station ■Head module:
00H to FEH
*2
■Modules other than the head
module:
00H (fixed)
16-bit unsigned binary ANY16
(s4) Start address of the buffer memory area of the
intelligent device station or the remote device station
to which the data is written
0000H to FFFFFFFFH (0 to
4294967295)
32-bit unsigned binary ANY32
(s5) Start device of the own station, where the write-
target data is stored
Device name ANY16
*3
(n) Number of write data points (in units of words) 1 to 240 16-bit unsigned binary ANY16
(d) Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error, (d)+1
also turns on.
Bit ANYBIT_ARRAY
(Number of elements:
2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
(J)
X, Y, M, L,
SM, F, B,
SB, FX, FY
J\ T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(J)
(s1)
*1
*2
(s2)
*1
*2
(s3)
*1
*2
(s4)
*1
*2
(s5)
*2
(n)
*1
*2
(d)
*1
*3