EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 1768

Mitsubishi Electric MELSEC iQ-R Series
2110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1766
22 POSITIONING INSTRUCTIONS
22.1 Restoring the Absolute Position
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Applicable devices
*1 FX and FY cannot be used.
*2 T, ST, C, and FD cannot be used.
*3 FD cannot be used.
Control data
Operand Description Range Data type Data type (label)
(U) G.ABRST Start I/O number (first three digits in four-digit
hexadecimal representation) of a module
00H to FEH 16-bit unsigned binary ANY16
Z.ABRST Start I/O number (first three digits in four-digit
hexadecimal representation) of a module
00H to FEH String ANY16_OR_STRING_S
INGLE
(s) Start device where the control data is stored Refer to the control data. Device name ANY16
*1
(d) Device to be turned on one scan upon completion of
instruction
If the instruction is completed with an error, (d)+1 is also
turned on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
(U)
X, Y, M, L,
SM, F, B, SB,
FX, FY
J\ T, S T, C, D,
W, SD, SW,
FD, R, ZR,
RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(U) G.ABRST  
Z.ABRST 
(s) 
*3

(d)
*1

*2

Operand: (s)
Device Item Description Setting range Set by
+0 System area 
+1 Completion status The instruction completion status is stored.
0: Completed successfully
Other than 0: Completed with an error (error code)
System
+2 Signal received from the servo amplifier Write the signal status, below, imported from the servo amplifier
to the input module.
b0: ABS data bit 0
b1: ABS data bit 1
b2: Send data ready flag
0, 1 User
+3 Signal to be sent to the servo amplifier Performs the operation with the dedicated instruction by using
the "Signal received from the servo amplifier" in (s)+2. The ON/
OFF state of the following data, output to the servo amplifier, is
stored.
b0: Servo on
b1: ABS transfer mode
b2: ABS request flag
System
+4 Status Status of communication with the servo amplifier
0: Communication complete (set by the user at start of
communication)
Other than 0: Now communicating (stored by the system)
0User/
system
+5 to +7 System area 

Table of Contents