27 ARITHMETIC OPERATION FUNCTIONS
27.2 Multiplication
1909
27
Operation result
1. Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2. Function with EN/ENO
The execution conditions and operation results will be as follows.
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
If the operation result is outside the data type range, convert the input value as appropriate before operation.
Operation error
When (s1) to (s28) are of REAL data type
When (s1) to (s28) are of LREAL data type
Execution condition Operation result
EN ENO (d)
TRUE (executed) TRUE Operation result output value
FALSE (not executed) FALSE
*1
Undefined value
Error code
(SD0)
Description
3402H The value input to (s1) to (s28) is -0, a subnormal number, NaN (not a number), or .
3403H The data output from (d) exceeds the following range. (An overflow has occurred.)
|(d)|<2
128
Error code
(SD0)
Description
3402H The value input to (s1) to (s28) is -0, a subnormal number, NaN (not a number), or .
3403H The data output from (d) exceeds the following range. (An overflow has occurred.)
|(d)|<2
1024