8. BUS CONNECTION
8.2 System Configuration
8 - 21
8
BUS CONNECTION
8.2.5 Connection to motion controller CPU
(A273UCPU, A273UHCPU(-S3), A373UCPU(-S3))
When one GOT is connected
*1 When installing the GOT 30m or more away from the main base unit, the bus connector conversion box is required.
*2 When using GT15-C EXSS-1, connect as the following precautions.
8.4.1 GT15-C [ ] EXSS-1, GT15-C [ ] BS
*3 When using the following functions, use GT15-QBUS(2). GT15-75QBUS(2)L cannot be used.
Remote personal computer operation (Serial), video display function, multimedia function, external I/O device, RGB display
function, sound output function
Extension base
unit
Bus extension
connector box
GOTMain base unit
Connection cable 1)
Connection cable 2)
Extension cable
Communication driver
Bus(A/QnA)
PLC
Connection cable 2)
GOT1000 Series
Max. distance
Main
base
Extension cable
Extens
ion
base
Connection cable 1)
Bus
connector
conversion
box
*1
Option device
*3
Model
Main
base
--
--
GT15-A370C12B-S1(1.2m)
GT15-A370C25B-S1(2.5m)
GT15-75ABUSL
GT15-75ABUS2L
GT15-ABUS
GT15-ABUS2
Between main base
and GOT: 2.5m
GT15-A370C12B(1.2m)
GT15-A370C25B(2.5m)
A7GT
-CNB
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
GT15-C300EXSS-1(30m)
*2
GT15-75ABUSL
GT15-75ABUS2L
GT15-ABUS
GT15-ABUS2
Between main base
and GOT: 32.5m
(Including between
main base and bus
connector conversion
box)
Between main base
and bus connector
conversion box: 2.5m
Main
base
GT15-
A370C12B(1.2m)
GT15-
A370C25B(2.5m)
Extens
ion
base
--
GT15-C12NB(1.2m)
GT15-C30NB(3m)
GT15-C50NB(5m)
GT15-75ABUSL
GT15-75ABUS2L
GT15-ABUS
GT15-ABUS2
Between main base
and GOT: 6.6m
(Including the
extension cable
length)
GT15-AC06B(0.6m)
GT15-AC12B(1.2m)
GT15-AC30B(3m)
GT15-AC50B(5m)
A7GT
-CNB
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
GT15-C300EXSS-1(30m)
*2
GT15-75ABUSL
GT15-75ABUS2L
GT15-ABUS
GT15-ABUS2
Between main base
and GOT: 36.6m
Between main base
and bus connector
conversion box: 6.6m
(Including the
extension cable
length)

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive

Related product manuals