15. SERVO AMPLIFIER CONNECTION
15.7 Precautions
15 - 45
SERVO AMPLIFIER CONNECTION
15
15.7 Precautions
Station number setting in the servo system
Make sure to establish servo system with the station
number set with the host address.
For details of host address setting, refer to the
following.
15.4.1 Setting communication interface
(Communication settings)
GOT clock function
Since the servo amplifier does not have a clock
function, the settings of [Adjust] or [Broadcast] by GOT
clock control will be disabled.
Servo amplifier/test operation using the GOT
During the servo amplifier/test operation, when the
communication between the GOT and the servo
amplifier is interrupted for 0.5[ms] or more, the servo
amplifier decelerates, stops, and then gets into the
servo lock status. During the servo amplifier/test
operation, continue the communication constantly by
monitoring the status display of the servo amplifier on
the GOT screen, etc.

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive