14. INVERTER CONNECTION
14.5 FREQROL Series Inverter Side Settings
14 - 35
INVERTER CONNECTION
14
HINTHINTHINT
(1) Automatic setting with Pr.999
If Pr.999 is set as the following, the communication settings other than [PU communication station number]
and [Communication EEPROM write selection] can be automatically set in a batch to the default
communication settings of the GOT side.
*1 When monitoring the value of Pr.999, 9999 is always monitored.
(2) Inverters available for automatic batch setting
Parameters are not automatically set in a batch depending on the SERIAL (production number) symbol of the
inverter to be used. For details, contact your local distributor.
Parameter No. Set value Description
Operation in parameter setting mode
Pr.999
*1
10 GOT Initial settings (PU connector)
[AUTO] [GOT] [1]Write
11 GOT Initial settings (RS-485)
-