17. CNC CONNECTION
17.5 CNC Side Settings
17 - 19
17
CNC CONNECTION
(b) Example of GX Developer setting
For details of the parameter setting, refer to the
following.
C6/C64/C64T NETWORK INSTRUCTION
MANUAL BNP-B2373
POINTPOINTPOINT
IP address setting
IP address setting on GX Developer is invalid.
Set the IP address by the 7-segment LED and rotary
switch of the CNC side, referring to the next page.
(2) CNC side parameter setting
Confirm the CNC side parameter setting with the
settings of IP address, gateway address, subnet mask
and port No. by the 7-segment LED and rotary switch of
the CNC side.
For details of the parameter setting operation, refer to
the following.
C6/C64/C64T NETWORK INSTRUCTION
MANUAL BNP-B2373 IV Setting the Ethernet
IP Address
7-segment LED
Rotary switch

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive

Related product manuals