2. DEVICE RANGE THAT CAN BE SET
2 - 3
2
DEVICE RANGE THAT CAN BE SET
Setting item
(For MELSEC-Q/QS, Q17nD/M/NC/DR, CRnD-700)
(For MELSEC-FX)
When selecting buffer memory (G) with the following controllers
MELSEC-QnU/DC, Q17nD/M/NC/DR, CRnD-700
MELSEC-L
MELSEC-QnA/Q/QS, MELDAS C6 *
MELSEC-Q(MULTI)/Q MOTION
Item Description
Device
Set the device name, device number, and bit number.
The bit number can be set only by specifying the bit of word device.
When setting buffer memory (BM) and (G), set the buffer memory address in the space for the device number.
Block
Set the block number of the extended file register.
This item can be set only when the extended file register (ER) is selected.
Intelligent
function
module
Unit top I/O
Set when the buffer memory (BM) is selected.
Set the head I/O number of the buffer memory for the intelligent function module.
Set the first 2 digits of the 3-digit head I/O number.
Unit No.
Set when the buffer memory (G) is selected.
Set the head I/O number of the buffer memory for the intelligent function module.
Set the first 2 digits of the 3-digit head I/O number.
MELSEC-
FX buffer
memory
Mask type
Set for using the buffer memory of MELSEC-FX series.
Set the mask type for monitoring or writing only specified bits of the buffer memory.
(4) Setting of the mask type (MELSEC-FX)
Unit No.
Set for using the buffer memory of MELSEC-FX series.
Set the module No. of the special function unit or special function block to monitor or write.
(5) Setting of the module No. (MELSEC-FX)
Information Displays the device type and its setting range selected in [Device].
Network
Set the station number of the controller to be monitored.
CPU No.
Set the CPU No. of the controller.
(1) Setting of the CPU No.
Host Select this item for monitoring the host controller.
Other
Select this for monitoring other controllers.
After selecting the item, set the station number and network number of the controller to be
monitored.
NW No.: Set the network No.
Station No.: Set the station No.
Swich to the device
comment dialog
Reading the device comment data created by GX Developer and confirming the device comment/device name are
available during device setting.
For details on the procedure to refer to the device comment, refer to the following.
GT Designer3 (GOT2000) Help

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive

Related product manuals