EasyManua.ls Logo

MUTOH ValueJet - Page 324

MUTOH ValueJet
392 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ValueJet 1304 Service manual
AP-74109 Rev 1.1 9-10
(1) CPU system serious error
Table 9-4 Symptoms and Check Items for CPU System Serious Errors
No. Message Event/
symptom
Check item Action Reference
1 E 016 error
Interrupt
[00]
Interruption
exception
error:
Abnormal
condition in
interruption
process.
1. Check AC power
supply and printer
surrounding
equipment.
2. Check reappearance
by turning ON/OFF
the machine power
several times. Make
sure to perform this
check repeatedly
even if no problems
seem to be present.
(Make the same
condition as user's.)
Contact our customer
support center.
Operation
Manual
2 E 016 error
TLB Modif
[01]
Command
border
exception/TLB
exception (load
or command
fetch) error:
Abnormal
condition in
command
border.
Or TLB
exception in
data load or
command
fetch.

Table of Contents

Related product manuals