EasyManua.ls Logo

MUTOH Valuevet VJ-628X - Page 302

MUTOH Valuevet VJ-628X
423 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.6.5 Uni-D/ Bi-D Adjustment Menu 302
5.6 Adjustment Menu VJ628XE-M-00
(5) Setup menu
Select the Setup menu for parameter, and then press [Enter] to renew the parameter.
㨀㧵㧼
The default value is set to values that are suited for Mutoh ink.
Enter setting values from panel.
(5-a)Uni-D Setup
㨀㧵㧼
The default values for Uni-D adjustment is set to all "0" regardless of
carriage speed and head height.
Inputting Uni-D adjustment value (when Uni-D 320 VSD1 is selected)
(5-b)Bi-D Setup
㨀㧵㧼
The default values for Bi-D adjustment is as follows:
Inputting Bi-D adjustment value (when Bi-D 320 VSD4 is selected)
>@
>!@
[Enter]
[Enter]
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹀㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹆㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹅㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹄㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹃㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㹂㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂㸱㸰㸮ࠉ㹔㸯ࠉ㸡㸯ࠉ㸿㸸ࠉࠉࠉ㸮
㹓㹬㹧㹂ࠉ㹃㹌㹂
Press [+] or [-] key to change
the setting values.
adjustment unit
1 / 720 inch=approx. 35ȣm
adjustment range-100100
C is not printed, beacause
the position is reffered as the basis
when adjusting.
#1Head Gap Low
#2Head Gap High
㹓㹬㹧࣮㹂ࠉ㸱㸰㸮ࠉ㹔㹑㹂㸯㸸㹑㹣㹲㹳㹮
㹊㹭㹵ࠉ㸯㸸㹓㹬㹧࣮㹂ࠉ㸱㸰㸮ࠉ㹔㹑㹂㸯
[Enter]
[Enter]
Item default
values
Item default
values
BiD Low 320 VSD1 -40 BiD High 320 VSD1 -78
320 VSD3 -42 320 VSD3 -92
320 VSD4 -36 320 VSD4 -81
400 VSD1 -53 400 VSD1 -100
400 VSD3 -54 400 VSD3 -114
400 VSD4 -47 400 VSD4 -100
>@
>!@
[Enter]
㹀㹧㹂ࠉ㸱㸰㸮ࠉ㹔㹑㹂㸲ࠉ㸡㸯㸸ࠉࠉࠉ㸮
㹀㹧㹂ࠉ㹃㹌㹂
㹀㹧࣮㹂ࠉ㸱㸰㸮ࠉ㹔㹑㹂㸲㸸㹑㹣㹲㹳㹮
㹊㹭㹵ࠉ㸷㸸㹀㹧࣮㹂ࠉ㸱㸰㸮ࠉ㹔㹑㹂㸲
[Enter]
[Enter]
Press [+] or [-] key to change
the setting values.
adjustment unit1 / 2880 inch
adjustment range-400400
#1Head Gap Low
#2Head Gap Low

Table of Contents