3.5.5 Replacing FG Cable Assy 80
3.5 Replacing Board Base section VJ628XE-M-00
3.5.5 Replacing FG Cable Assy
● Tools & Jigs & Maintenance part
• Before replacing Board Assy and pulling or pushing cables, unplug Power cable
and leave it for a while.
If operating with Power cable still plugged, Board may be damaged or operators
may get an electric shock by residual electric charge.
Name No. Remarks
FG Cable Assy DG-43741 Exploded View Board Box
Phillips screwdriver No.2 Generic
products
-
1 Remove Top Cover.
3.2.1 Removing Top Cover
2 Remove the screw retaining FG Cable Assy.
A : FG Cable
B : Tapping screw M4x6S Tight cup
3 Remove FG Cable Assy from AC Inlet.
C : AC Inlet
4 Replacing FG Cable.
5 To reassemble unit, reverse the removal
procedure.