EasyManuals Logo

Oce PlotWave 900 User Manual

Oce PlotWave 900
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Enable or disable the failsafe option
1.
Open Océ Express WebTools and log in as 'System administrator'.
2.
Open the 'Configuration' - 'Connectivity' tab.
3.
Go to the 'IPsec generic' bar.
4.
Click on Edit in the upper right-hand corner of the section.
5.
Choose the setting for the 'Failsafe option'; select either 'Disabled' or 'Enabled'.
Note:
'When enabled, HTTP communication remains possible with all hosts, with no encryp-
tion, even when IPsec is enabled. All functionality of Express WebTools, including job
submission, uses HTTP. Once IPsec is configured correctly and working satisfactorily,
this option can be disabled.'
Chapter 3 - Define your workflow with Océ Express WebTools78
Enable IPSec

Table of Contents

Other manuals for Oce PlotWave 900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oce PlotWave 900 and is the answer not in the manual?

Oce PlotWave 900 Specifications

Océ PlotWave 900

Media Handling IconMedia Handling
tray capacity2 x 750 sheets - 20lb Bond
media width8.5” x 36”
media length8.5” x 48”
media weight16 - 29 lb Bond
Sound Levels IconSound Levels
sound level standby≤ 35 dB (A)
sound level active≤ 71 dB (A)
Electrical IconElectrical
voltage100 – 240 V
frequency50 – 60 Hz
Weight and Dimensions IconWeight and Dimensions
required floor space59.1” (W) x 63.0” (D) x 43.3” (H)
weight309 lbs.

Océ TDS750

Electrical IconElectrical
voltage100 – 240 V
frequency50 – 60 Hz