Create a network destination with SMB
1.
Create a shared folder on a workstation. For example c:\Scan
2.
Click 'Configuration' - 'Scan destinations'.
3.
Click 'Edit' in a 'Scan destinations' bar.
4.
Enter a name for the scan destination.
This name will appear on the scanner operator panel.
5.
Place a check mark in the enabled box.
6.
Select 'Remote via SMB'.
7.
If you defined a username and a password for the shared folder on the remote PC, enter
the remote username and the remote password in the required fields.
Note:
Make sure the user has write-access privileges on the destination.
Note:
If the remote workstation uses domains, you must enter "domain_name\username" as
the remote username and the password for this user in this domain.
8.
Enter the path name of the remote folder.
The path name is the "hostname-of-remote-workstation\sharename[\path]". This is
case sensitive.
Note:
Find the system name of the remote workstation on the control panel of the workstation
(Control panel - Network - Identification - System name)
9.
Enter a file name for your scanned files.
The file extension depends on the scanned file type that you select when you start your
scan job on the scanner operator panel.
If you enter a generic name, for example: scan###.*, the scanned files automatically get
a unique file name. An ascending number replaces the "###".
10.
Enter a start value for ###. If you enter 001, the first scanned file is named scan001.*.
11.
Click 'Ok' to confirm your entries or 'Cancel' to reject your entries.
Note:
If for any reason a scanned file cannot be delivered to the remote destination, the file is
sent to the local 'Scans' Inbox.
Chapter 3 - Define your workflow with Océ Express WebTools90
Configure a remote scan destination

Table of Contents

Other manuals for Oce PlotWave 900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oce PlotWave 900 and is the answer not in the manual?

Oce PlotWave 900 Specifications

Océ PlotWave 900

Media Handling IconMedia Handling
tray capacity2 x 750 sheets - 20lb Bond
media width8.5” x 36”
media length8.5” x 48”
media weight16 - 29 lb Bond
Sound Levels IconSound Levels
sound level standby≤ 35 dB (A)
sound level active≤ 71 dB (A)
Electrical IconElectrical
voltage100 – 240 V
frequency50 – 60 Hz
Weight and Dimensions IconWeight and Dimensions
required floor space59.1” (W) x 63.0” (D) x 43.3” (H)
weight309 lbs.

Océ TDS750

Electrical IconElectrical
voltage100 – 240 V
frequency50 – 60 Hz