Orion Networks
A10E/A28E/A28F Configuration Guide
6 Security
Orion Networks
194
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#pppoeagent
circuit-id mode { onu |
switch }
Configure the padding mode of the Circuit
ID.
3
Alpha-
A28E(config)#interface port
port-id
Enter physical layer interface configuration
mode.
4
Alpha-A28E(config-
port)#pppoeagent circuit-
id
string
(Optional) set the Circuit ID to the
customized string.
In default mode, the Circuit ID contains an attached string. By default, the attached string is
set to the hostname of the switch. You can set it to a customized string.
Configure the attached string of the Circuit ID for the A10E/A28E as below.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#pppoeagent
circuit-id attach-string
string
(Optional) configure the attached string of
the Circuit ID.
If the Circuit ID is in default mode, attached
string configured by this command will be
added to the Circuit ID.
Configuring Remote ID
The Remote ID is padded with a MAC address of the switch or a client. In addition, you can
specify the form (binary/ASCII) of the MAC address.
Configure Remote ID for the A10E/A28E as below.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-A28E(config)#interface
port
port-id
Enter physical layer interface
configuration mode.
3
Alpha-A28E(config-
port)#pppoeagent remote-id
{ client-mac | switch-mac }
(Optional) configure PPPoE+ Remote ID
to be padded with the MAC address.
4
Alpha-A28E(config-
port)#pppoeagent remote-id
format { ascii | binary }
(Optional) configure the padding modes of
the PPPoE+ Remote ID.

Table of Contents