EasyManua.ls Logo

Orion A10E - Figure 6-12 Configuring Pppoe

Orion A10E
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Orion Networks
A10E/A28E/A28F Configuration Guide
6 Security
Orion Networks
196
Set the attached string of the Circuit ID to alpha-a28e. Set the padding content of the
Circuit ID on Port 1 to user01. Set the padding content of the Remote ID on Port 2 to the
MAC address of the client. The padding contents are in ASCII mode.
Enable Tag overriding on Port 1 and Port 2.
Figure 6-12 Configuring PPPoE+
Configuration steps
Step 1 Set Port 3 to the trusted interface.
Alpha-A28E#config
Alpha-A28E(config)#interface port 3
Alpha-A28E(config-port)#pppoenagent trust
Alpha-A28E(config-port)#exit
Step 2 Configure packet information of Port 1 and Port 2.
Alpha-A28E(config)#pppoeagent circuit-id attach-string alpha-a28e
Alpha-A28E(config)#interface port 1
Alpha-A28E(config-port)#pppoeagent circuit-id user01
Alpha-A28E(config-port)#exit
Alpha-A28E(config-port)#interface port 2
Alpha-A28E(config-port)#pppoeagent remote-id client-mac
Alpha-A28E(config-port)#pppoeagent remote-id format ascii
Alpha-A28E(config-port)#exit
Step 3 Enable Tag overriding on Port 1 and Port 2.
Alpha-A28E(config)#interface port 1
Alpha-A28E(config-port)#pppoeagent vendor-specific-tag overwrite enable
Alpha-A28E(config-port)#exit
Alpha-A28E(config)#interface port 2
Alpha-A28E(config-port)#pppoeagent vendor-specific-tag overwrite enable
Alpha-A28E(config-port)#exit

Table of Contents