A10E/A28E/A28F Configuration Guide
8 OAM
Orion Networks
286
8.3.7 Example for configuring SLA
Networking requirements
As shown in Figure 8-6, the PC communicates with the server through the network consisting
of by Switch A, Switch B and Switch C. You can deploy CFM feature on switches to make the
Ethernet link between the server and the PC to reach the telecom-grade level. SLA is
deployed on Switch A to effectively carry out SLA agreement signed with the users. SLA is
periodically scheduled to test the network performance between Switch A and Switch C.
Conduct Layer 2 delay test on Switch A towards Switch C. Configure the y1731-echo
operation on Switch A, with operation number of 2, remote MEP of 2, MD level of 3, VLAN
ID of 100, CoS of 0, life period of scheduling of 20s, and test period of 10s.
Figure 8-6 SLA application networking
Configuration steps
Step 1 Configure CFM on Switches.
For details, see section 8.2.11 Example for configuring CFM.
Step 2 Configure y1731-echo operation on Switch A, and enable operation scheduling.
SwitchA#config
SwitchA(config)#sla 2 y1731-echo remote-mep 302 level 3 svlan 100 cos 0
SwitchA(config)#sla schedule 2 life 20 period 10
Checking configurations
Use the show sla configuration command on Switch B to see whether SLA configurations
are correct.
Switch_B#show sla 1 configuration
----------------------------------------------------------