Loading...
Orion Networks
A10E/A28E/A28F Configuration Guide
9 System management
Orion Networks
336
Severity
Level
Description
Alert
1
Need to deal immediately.
Critical
2
Serious status
Error
3
Errored status
Warning
4
Warning status
Notice
5
Normal but important status
Informational
6
Informational event
Debug
7
Debugging information
The severity of output information can be manually set. When you send information
according to the configured severity, you can just send the information whose
severity is less than or equal to that of the configured information. Such as, when the
information is configured with the level 3 (or the severity is errors), the information
whose level ranges from 0 to 3,that is, the severity ranges from emergencies to
errors, can be sent.
9.7.2 Preparing for configurations
Scenario
The A10E/A28E generates critical information, debugging information, or error information
of the system to system logs and outputs the system logs to log files or transmit them to the
host, Console interface, or monitor for viewing and locating faults.
Prerequisite
N/A
9.7.3 Default configurations of system log
The default configuration of system log is as below.
Function
Default value
System log
Enable
Output log information to Console
Enable, the default level is information (6).
Output log information to host
N/A, the default level is information (6).
Output log information to file
Disable, the fixed level is warning (4).
Output log information to monitor
Disable, the default level is information (6).
Log Debug level
low
Note