1 Basic configurations
Orion Networks
19
1.4.4 Checking configurations
Use the following commands to check configuration results.
No.
Item
Description
1
Alpha-A28E#show startup-config
[
file-name
]
Show configuration information loaded
upon device startup.
2
Alpha-A28E#show running-config
[ interface port [
port-id
] ]
Show the running configuration
information.
1.5 Configuring clock management
1.5.1 Configuring time and time zone
To ensure the A10E/A28E to work well with other devices, you must configure system time
and belonged time zone accurately.
The A10E/A28E supports three types of system time mode, which are time stamp mode,
auxiliary time mode, and default mode from high to low according to timing unit accuracy.
You need to select the most suitable system time mode by manual in accordance with actual
application environment.
The default configuration of time and time zone is as below.
Function
Default value
System time
2000-01-01 08:00:00.000
System clock mode
default
System belonged time zone
UTC+8
Time zone offset
+08:00
Functional status of Daylight Saving Time
Disable
Configure time and time zone for the A10E/A28E as below.
Step
Configuration
Description
1
Alpha-A28E#clock set
hour minute
second year month day
Configure system time.
2
Alpha-A28E#clock timezone { + |
- }
hour minute timezone-name
Configure system belonged time zone.
3
Alpha-A28E#clock mode
{ auxiliary | default |
timestamp }
Configure system clock mode.