EasyManua.ls Logo

Orion A10E - Figure 7-2 Configuring Static LACP Link Aggregation; Example for Configuring Static LACP Link Aggregation

Orion A10E
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Orion Networks
A10E/A28E/A28F Configuration Guide
7 Reliability
Orion Networks
211
Configure Switch A.
SwitchA(config)#trunk enable
Configure Switch B.
SwitchB(config)#trunk enable
Checking results
Show global configurations on manual link aggregation by the command of show trunk.
SwitchA#show trunk
Trunk: Enable
Loading sharing mode: SMAC
Trunk Group Mode Member Ports Efficient Ports
-----------------------------------------------------------
1 manual 1,2 1,2
7.1.8 Example for configuring static LACP link aggregation
Networking requirements
As shown in Figure 7-2, to improve link reliability between Switch A and Switch B, you can
configure a static LACP link aggregation between these 2 devices. Add Port 1 and Port 2 into
one link aggregation group, where Port 1 is used as the current link and Port 2 is the
protection link.
Figure 7-2 Configuring static LACP link aggregation

Table of Contents