EasyManua.ls Logo

Orion A10E - Entering Remote Configuration Mode; Optional) Showing Remote Extended OAM Capacity

Orion A10E
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Orion Networks
A10E/A28E/A28F Configuration Guide
9 System management
Orion Networks
319
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#extended-oam
config-request enable
Enable power-on configuration request.
3
Alpha-
A28E(config)#extended-oam
notification enable
Enable sending extended OAM
notification packet.
9.5.6 Entering remote configuration mode
The interface can enter remote configuration mode only when OAM link is
established between CO device and remote device.
Take the following configuration on CO device.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-A28E(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
3
Alpha-A28E(config-port)#remote-
device
Enter remote configuration mode.
4
Alpha-A28E(config-
remote)#interface client
client-id
Alpha-A28E(config-remoteport)#
(Optional) enter remote interface
configuration mode.
9.5.7 (Optional) showing remote extended OAM capacity
Whether the remote device supports this function varies with the specific remote
device. For details, see the corresponding manuals.
On the CO device, you can use the command of show oam capability to show remote device
extended OAM capacity, and then take configuration according to the specific device.
Configure the CO device as below.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#interface
interface-type interface-
number
Enter physical layer interface
configuration mode.

Table of Contents