A10E/A28E/A28F Configuration Guide
After basic information of an operation (distinguished by operation number) is
configured, the operation cannot be modified or reconfigured. If you need to
modify the operation, delete the operation and then reconfigure it.
SLA supports at most 100 operations being scheduled at one time, but wait a
schedule to finish (reach schedule life time or stop schedule) before schedule
again or modify schedule information.
8.3.5 Configuring SLA scheduling
Configure SLA scheduling information for the A10E/A28E as below.
Enter global configuration mode.
Alpha-
A28E(config)#sla
schedule
oper-num
[ life { forever |
life-time
} ]
[ period
period
]
[ begin ]
Configure SLA operation scheduling information,
and enable SLA operation scheduling.
By default, SLA operation scheduling is disabled.
If you use the begin parameter, the
configuration will be loaded upon device
startup, without actual scheduling
operations. If you does use the begin
parameter, scheduling operations will be
performed.
8.3.6 Checking configuration
Use the following commands to check configuration results.
Alpha-A28E#show sla
{ all |
oper-num
}
configuration
Alpha-A28E#show sla
{ all |
oper-num
}
result
Show test information of last SLA operation.
Alpha-A28E#show sla
{ all |
oper-num
}
statistic
Show statistics of operation scheduling. The same
operation (distinguished by operation number) can
be taken statistics of for 5 groups. If more groups
have to be taken statistics of, the oldest (according
to start time of scheduling) group will be aged.