EasyManua.ls Logo

Orion A10E - Checking Configurations; Cli; Introduction

Orion A10E
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Orion Networks
A10E/A28E/A28F Configuration Guide
1 Basic configurations
Orion Networks
6
Step
Configuration
Description
7
Alpha-
A28E(config)#ssh2
server
authentication-
retries
times
(Optional) configure the allowable failure times
for SSHv2 authentication. The A10E/A28E refuses
to authenticate and then closes the connection
when client authentication failure numbers exceeds
this overtemperature threshold.
8
Alpha-
A28E(config)#ssh2
server port
port-id
(Optional) configure SSHv2 snooping port
number.
When configuring SSHv2 snooping port
number, the input parameter cannot take
effect until SSHv2 is restarted.
9
Alpha-
A28E(config)#ssh2
server session
session-list
enable
(Optional) enable SSHv2 session on the
A10E/A28E.
1.1.5 Checking configurations
Use the following commands to check the configuration results.
No.
Configuration
Description
1
Alpha-A28E#show telnet-server
Show configurations of the Telnet
server.
2
Alpha-A28E#show ssh2 public-key
[ authentication | rsa ]
Show the public key used for SSHv2
authentication on the A10E/A28E and
client.
3
Alpha-A28E#show ssh2 { server |
session }
Show SSHv2 server or session
information.
1.2 CLI
1.2.1 Introduction
CLI is the path for communication between user and the A10E/A28E. You can complete
device configuration, monitor and management by executing relative commands.
You can log in to the A10E/A28E through PC that run terminal emulation program or the
CPE device, enter into CLI once the command prompt appears.
The features of CLI:
Local configuration via Console interface is available.
Note

Table of Contents