A10E/A28E/A28F Configuration Guide
Alpha-A28E(config-
remote)#snmp-server community
community-name
{ ro | rw }
Configure remote read/write
community and read/write authority.
Configuring remote Trap
The remote device generates Trap information, which will be sent to CO device through OAM
notification packet and then CO device will send the Trap to network management system.
To configure network management system to accept remote Trap, you need to enable remote
Trap function on CO device and maybe enable to send extended OAM notification function
on remote device.
Configure the CO device as below.
Enter global configuration mode.
Alpha-A28E(config)#snmp trap
remote enable
Enable remote device to send Trap
function.
To configure remote Trap, some remote devices need to perform the command of
extended-oam notification enable to enable to send extended OAM notification
function in remote configuration mode.
9.5.14 Configuring remote VLAN
Whether the remote device supports this function varies with the specific remote
device. For details, see the corresponding manuals.
Different remote devices may have different configuration commands.
You can configure remote VLAN and deal with packets received by the remote device
according to VLAN property configuration, such as set remote VLAN status, VLAN tag
property and create remote VLAN group, etc.
Remote VLAN status:
dot1q: remote VLAN mode is Dot1q; the packets entering device interface will be
forwarded in accordance with dot1q mode.
forbid: forbid remote VLAN function; the packets entering device interface will be
forwarded in accordance with transparent transmission mode.
port: remote VLAN is Port mode.
Enable remote VLAN CoS function, deal with the packets entering device interface according
to VLAN priority, high priority first and low priority second.