A10E/A28E/A28F Configuration Guide
triggered when the monitored variable is abnormal. The event cannot be successfully trigged
unless the event is established.
The alarm will be triggered as long as the upper or lower threshold of the event in the event
table is matched. The alarm is not generated even when alarm conditions are matched if the
event related to the upper/lower threshold (rising-event-id or falling-event-id) is not
configured in the event table.
Configure RMON alarm group for the A10E/A28E as below.
Enter global configuration
mode.
Alpha-A28E(config)#rmon alarm
alarm-id
mibvar
[ interval
period
] { absolute | delta }
rising-threshold
rising-value
[
rising-event-id
] falling-
threshold
falling-value
[
falling-
event-id
] [ owner
owner-name
]
Add alarm instances to the
RMON alarm group and
configure related parameters.
9.3.7 Configuring RMON event group
Configure RMON event group for the A10E/A28E as below.
Enter global configuration
mode.
Alpha-A28E(config)#rmon event
event-id
[ log ] [ trap ]
[ description
string
] [ owner
owner-name
]
Add events to the RMON event
group and configure processing
modes of events.
9.3.8 Checking configurations
Use the following commands to check configuration results.
Show RMON configurations.
Alpha-A28E#show rmon
alarms
Show RMON alarm group information.
Alpha-A28E#show rmon
events
Show RMON event group information.
Alpha-A28E#show rmon
statistics [ port
port-id
| ip
if-number
]
Show RMON statistics group information.
Alpha-A28E#show rmon
history { port
port-id
|
ip
if-number
}
Show RMON history group information.