A10E/A28E/A28F Configuration Guide
SwitchC(config)#ethernet cfm enable
Step 3 Execute CFM fault acknowledgement.
Take Switch A as an example.
Switch(config)#service ma1 level 3
Switch(config-service)#ping mep 302 source 301
Sending 5 ethernet cfm loopback packets to 000e.5e03.688d, timeout is 2.5
seconds:
!!!!!
Success rate is 100 percent (5/5).
Ping statistics from 000e.5e03.688d:
Received loopback replys:< 5/0/0 > (Total/Out of order/Error)
Ping successfully.
Step 4 Execute CFM fault location.
Take Switch A as an example.
SwitchA(config-service)#traceroute mep 302 source 301
TTL: <64>
Tracing the route to 000E.5E00.0002 on level 3, service ma1.
Traceroute send via port1.
-------------------------------------------------------------------------
Hops HostMac Ingress/EgressPort IsForwarded RelayAction NextHop
-------------------------------------------------------------------------
1 000E.5E00.0003 2/1 Yes rlyFdb 000E.5E00.0003
2 000E.5E00.0003 1/2 Yes rlyFdb 000E.5E00.0001
3 000E.5E00.0001 1/- No rlyHit 000E.5E00.0002
Checking result
Show CFM configuration on Switch by the command of show ethernet cfm.
Take Switch A as an example.
SwitchA#show ethernet cfm
Global cfm Status: enable
Port CFM Enabled Portlist: 1-10
Archive hold time of error CCMs: 100(Min)
Remote mep aging time: 100(Min)
Device mode: Slave