Configure the CO device as below.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#interface
interface-type
interface-number
Enter physical layer interface configuration
mode.
3
Alpha-A28E(config-
port)#remote-device
Enter remote configuration mode.
4
Alpha-A28E(config-
remote)#interface
client
client-id
Enter remote interface configuration mode.
5
Alpha-A28E(config-
remoteport)#shutdown
(Optional) shut down remote interface.
6
Alpha-A28E(config-
remoteport)#speed
{ auto | 10| 100 }
(Optional) configure remote device Client
interface speed.
7
Alpha-A28E(config-
remoteport)#duplex
{ full | half }
(Optional) configure remote device Client
interface duplex mode.
The OAM link maybe disconnect after
configuring remote interface duplex
mode.
8
Alpha-A28E(config-
remoteport)#flowcontrol
{ on | off }
(Optional) enable/disable flow control on the
user interface of the remote device.
Configuring interface parameters in remote configuration mode
In remote configuration mode, configure remote interface auto-negotiation, interface
bandwidth, and failover, etc.
Configure the CO device as below.
Step
Configuration
Description
1
Alpha-A28E#config
Enter global configuration mode.
2
Alpha-
A28E(config)#interface
interface-type
interface-number
Enter physical layer interface configuration
mode.
3
Alpha-A28E(config-
port)#remote-device
Enter remote configuration mode.
4
Alpha-A28E(config-
remote)#description
{ line
line-id
|
client
client-id
}
string
(Optional) configure description of the
interface on the remote device.