Orion Networks
A10E/A28E/A28F Configuration Guide
9 System management
Orion Networks
332
Configuration steps
Step 1 Establish an OAM link between the RC551E and the switch.
Set the RC551E to work in OAM passive mode, and enable OAM.
Alpha-A28E#hostname RC55x
RC55x#config
RC55x(config)#oam passive
RC55x(config)#interface line 1
RC55x(config-port)#oam enable
Set the switch to work in OAM active mode, and enable OAM.
Alpha-A28E#hostname Switch
Switch#config
Switch(config)#oam active
Switch(config)#interface port 1
Switch(config-port)#oam enable
Step 2 Configure the host name and IP address of the RC551E on the switch.
Switch(config-port)#remote-device
Switch(config-remote)#hostname RC551E
Switch(config-remote)#ip address 192.168.18.100 255.255.255.0 200
Checking result
Show configurations of the remote device on the switch.
Alpha-A28E(config-remote)#show remote-device information
Local port:port1
Product Name: RC551E-4GEF
Hostname: RC551E
Operation Software Version: ROS_4.14.1670.RC551E-
4GEF.39.20110914
Hardware Version: Hardware RC551E-4GEF
Main chip id: N/A
Total ports: 6
FPGA chip id: N/A
FPGA soft version: N/A
IP Address/mask: 192.168.18.100/255.255.255.0
IP Interface Vlan: 0
Vlan member Port:
Untag port:
IP Default-gateway: 0.0.0.0
OutBand-port IP/Mask: N/A/N/A